INTENDED USE
The Melamine Plate Kit is a competitive ELISA for the quantitative analysis of Melamine in contaminated samples.
MATERIALS REQUIRED BUT NOT PROVIDED
• Laboratory quality distilled or deionized water.
• Pipet with disposable tips capable of dispensing 50 µL.
• Multi-channel pipet; 8 channel capable of dispensing 50 and 100 µL.
• Paper towels or equivalent absorbent material.
• Microwell plate or strip reader with 450nm filter.
• Timer
• Wash solution and bottle. PBST wash solution:10mM PBS + 0.05% Tween 20, pH 7.4.
The Methoprene Plate Kit is an immunological laboratory test for quantitative analysis of Methoprene in grains such as barley, corn, oat, rice or wheat.
The kit in its original packaging can be used until the end of the month indicated on the box label when stored at 2 – 8ºC.
1 Frame containing 12 antibody coated test strips of 8 wells each vacuum-packed in aluminized pouch with indicating desiccant.
1 vial each of 0, 0.1, 0.3 and 0.75 ppb Methoprene calibrators
1 vial of Methoprene Enzyme Conjugate.
1 vial containing 14 mL of Substrate.
1 vial containing 14 mL of Stop Solution. (Caution! 1N HCl. Handle with care.)
INTENDED USE
The Progesterone Plate Kit is an immunological laboratory test for the quantitation of Progesterone in dairy products such as milk, cheese, yogurt, cream, ice cream and butter.
REAGENTS AND MATERIALS PROVIDED
The kit in its original packaging can be used until the end of the month indicated on the box label when stored at 2 – 8ºC.
• 1 frame containing 12 test strips of 8 wells each, vacuum-packed in aluminized pouch with indicating desiccant.
• 4 vials each containing 4 mL Progesterone calibrators corresponding to 0, 0.1, 1 and 10 μg/L (ppb) Progesterone.
• 1 vial of 8 mL Progesterone-HRP Enzyme Conjugate.
• 1 vial of 8 mL Rabbit anti-Progesterone antibody.
• 1 vial containing 14 mL of Substrate.
• 1 vial containing 14 mL of Stop Solution. (Caution! 1N HCl.)
• 1 vial containing 8 mL of 1N HCl for extraction. (Handle with care!)
• 1 vial containing 50 mL of Wash Solution concentrate (10X).
INTENDED USE
The r-Metolachlor Plate Kit is an immunological laboratory test for the quantitative analysis of r-metolachlor herbicide residues in water samples.
MATERIALS PROVIDED IN THE PLATE KIT
The kit in its original packaging can be used until the end of the month indicated on the box label when stored at 2 – 8ºC.
1 Frame containing 12 antibody-coated test strips of 8 wells each vacuum-packed in the aluminized pouch with indicating desiccant.
1 vial each of 0, 0.1, 0.3, and 0.75 ppb r-Metolachlor calibrators
1 vial of r-Metolachlor Enzyme Conjugate.
1 vial containing 14 mL of Substrate.
1 vial containing 14 mL of Stop Solution. (Caution! 1N HCl. Handle with care.)
INTENDED USE
The r-Metolachlor Tube Kit is an immunological laboratory test for the quantitation of r-Metolachlor herbicide residues in water.
REAGENTS AND MATERIALS PROVIDED
The kit in its original packaging can be used until the end of the month indicated on the box label when stored at 2 – 8ºC.
2 bags each containing 20 test tubes coated with rabbit anti-2,4-D antibodies and desiccant.
1 vial of 10 ppm 2,4-D in calibrator stock solution.
1 vial of 2,4-D-HRP Enzyme Conjugate.
1 vial containing 60 mL of Substrate.
1 vial containing 60 mL of Stop Solution. (Caution! 1N HCl. Handle with care.)